Blast Parts / Level Switch

Level Switch

Capacitance level switch (KANSAI Automation Co., Ltd.) that detects the presence of powders, granules, liquids, or liquid-liquid interfaces by converting capacitance and conductance (impedance) changes at the probe into an electrical ON-OFF signal.

BLX Replacement & ALN Series Guide ALN vs. BLX

  • Primary Supply Model (ALN Compact Integral Type): We primarily supply the ALN integral series for its superior durability and field versatility.
  • Direct Replacement for Legacy BLX Models: Shares the same operating principle, power supply (AC 105V / 210V), probe dimensions (Ø22 / Ø18 / Ø12, L=250 mm), temperature rating (-25 to +80℃), and pressure rating (980 kPa) as the BLX series. Please verify power consumption (4.5 VA vs. 3.5 VA), minimum load current (100 mA vs. 10 mA — important for low-current PLC inputs), housing OD, and conduit thread size before replacement.
  • Upgraded ALN Specifications: Offers IP67 dust-tight and waterproof protection (vs. drip-proof on BLX) and double the relay contact capacity (10A vs. 5A), covering low and ultra-low sensitivity ranges in addition to high and standard sensitivity.
  • When replacing BLX (head OD Ø95 mm, conduit G 1/2") with ALN (head OD Ø114 mm, conduit G 3/4"), simply confirm surrounding clearance and conduit fitting size.

Key Features

  • No Moving Parts: Solid-state sensing with zero mechanical wear or jamming.
  • Broad Material Compatibility: Detects powders, granules, pellets, standard liquids, high-viscosity fluids, slurries, and interfaces between two immiscible liquids.
  • On-Site Sensitivity & Delay Adjustment: Built-in dial and potentiometers allow easy sensitivity calibration for material dielectric constants plus output time delay up to approx. 10 seconds.
  • Multiple Electrode Configurations: Beyond standard SUS304 straight rod probes, flat, wire-rope, PTFE-sleeved, and high-temperature probes are available.

Sensitivity Classes & Applications

Sensitivity ClassStable Detection RangeApplicable ModelsTypical Target Materials
1. High Sensitivity0.5 ~ 20 pFALN / BLXLow-dielectric materials: plastics (PVC, PP), granules, starch, cereals, cement, oil, LNG
2. Standard Sensitivity2 ~ 50 pFALN / BLXGeneral liquids and powders: water, adhesives, chemical solutions
3. Low Sensitivity20 ~ 1,000 pFALN OnlyConductive/viscous materials: acids, alkalis, chemicals, fertilizer, activated carbon, sludge
4. Ultra-Low Sensitivity5 ~ 35 ΩALN OnlyHigh-viscosity / highly conductive buildup: carbon black, ready-mix concrete

ALN vs. BLX Standard Specifications

SpecificationALN Series (Primary · Integral)BLX Series (Integral)
ConfigurationCompact Integral TypeCompact Integral Type
Power SourceAC 105V / 210V ±10% (50/60Hz)
※ DC 24V option available
AC 105V / 210V ±10% (50/60Hz)
Power Consumption4.5 VA3.5 VA
Output ContactSPDT × 1
Contact CapacityAC 250V 10A / DC 30V 10A (resistive)
※ Min. load current 100 mA (DC 24V)
AC 250V 5A / DC 30V 5A (resistive)
※ Min. load current 10 mA (DC 24V)
Detection Range1. High: 0.5~20 pF / 2. Standard: 2~50 pF
3. Low: 20~1,000 pF / 4. Ultra-Low: 5~35 Ω
1. High: 0.5~20 pF
2. Standard: 2~50 pF
Delay TimeApprox. 0 ~ 10 sec (adjustable potentiometer)
Amplifier Ambient Temp.-25 ~ +60℃ (non-freezing)
Standard Probe SizeØ22 / Ø18 / Ø12, L=250 mm (standard rod type)
Probe Operating Temp.-25 ~ +80℃ (non-freezing)
Probe Max. Pressure980 kPa (10 kgf/㎠)
Probe Bending LoadMax. 1 kN (100 kg) at L=250 mm
Vibration / ShockVibration: 2.0 mm amplitude, 600~3,600/min, 3 hrs all axes · Shock: 98 m/s² (10G) at probe
Ingress ProtectionIP67 (Dust-tight & Waterproof)Drip-proof
Housing / ConduitHead OD Ø114 mm · Conduit G 3/4" · Process R1Head OD Ø95 mm · Conduit G 1/2" · Process R1

Construction & Materials Standard Rod Bill of Materials

No.Part NameMaterialQty.
1HousingADC (Die-cast Aluminum)1
2Mounting ScrewSUS3041
3Earth ElectrodeSUS3041
4InsulatorPolyacetal1
5Main ElectrodeSUS3041

Amplifier Adjustment & Terminal Wiring

Level Switch Amplifier Terminals and Controls
  • INDICATOR: Lights up immediately upon material detection regardless of delay timer setting.
  • SENSITIVITY ADJ: Dial (scale 10–90) from L (lowest sensitivity) to H (highest sensitivity) to match target media.
  • COARSE: Coarse adjustment screw used to shift the baseline sensitivity range when dial range is insufficient.
  • DELAY: Potentiometer setting output relay delay up to approx. 10 seconds after detection.
  • Terminal Block: Connect relay output contacts (NO / COM / NC) and power supply (210V / 105V / AC0V) per nameplate rating.

Model Designation Code

ALN - 111 - 2

Example: ALN-111-2 — Compact integral type · Standard rod probe · Probe length ≤250 mm · Standard sensitivity

Configuration1: Compact Integral Type
Electrode Type1: Standard Rod · 2: Sheathed Rod · 3: Flat · 4: Wire-Rope · 5: Special
Electrode Length1: ≤250 mm · 2: 251~500 mm · 3: 501~1,000 mm · 4: 1,001~2,000 mm · 5: Other
Sensitivity Class1: High · 2: Standard · 3: Low · 4: Ultra-Low (※ BLX supports 1 & 2 only)
Heat-Resistant OptionBlank: Standard · H: High-Temperature
Quote & Spec Inquiry Tell us the model and specification and we will get back to you promptly.
+82-51-319-2332